Featured Product
This months featured product is the ADAM-4520 RS-232 to RS-485 converter.
Link to the Product Page
Products:
Contact us
Tel: 087-701-8559
Tel: 011-706-7913
Fax: 086-671-6808
Email: info@promicro.co.za
To email an enquiry: Click here
Physical:
52 Shepherd Avenue
Bryanston
2021
Postal:
P O Box 593
Cramerview
2060
Get Directions
External Links:
ADAM-6015 7-ch Isolated RTD Input Modbus TCP Module
Download the ADAM-6015 data sheet.
Overview
The ADAM-6015 7-channel RTD input module accepts a wide range of RTD sensor types, including Pt100, Pt1000, Ni50, Ni508, and Balco 500 series. Multi input ranges are allowed in one module, creating a cost-effective solution. Most important of all, the ADAM-6015 supports open wiring diagnostic function which warns operators when the sensor wire has been broken. It specifically aims at building and factory temperature monitoring applications.
Features
- I/O Type: 7 RTD
- 10/100Based-T Ethernet
- Supports multi-channel/multi-range
- Pt 100/1000, Ni, Balco 500
- Wiring burn-out detect function
- Easy mounting on DIN-rail , panel piggyback
- Supports Modbus/TCP
Specifications
Analog Input
- Channels 7 differential
- Resolution 16-bit
- Sampling Rate 10 samples/second
- Input Impedance >10 MΩ
- Input Type Pt, Ni and Balco RTD
- Input Connection 2 or 3 wire
- RTD Types and Input Ranges
- Pt RTD 100 ohms
Pt |
-50°C |
to |
+150°C |
Pt |
0°C |
to |
+100°C |
Pt |
0°C |
to |
+200°C |
Pt |
0°C |
to |
+400°C |
Pt |
-200°C |
to |
+200°C |
IEC RTD 100 Ohms (a=0.00385) |
JIS RTD 100 Ohms (a=0.00392) |
- PT 1000 RTD
- Balco 500 RTD
- Ni 518 RTD
Ni |
-80°C |
to |
+100°C |
Ni |
0°C |
to |
+100°C |
- Accuracy ±0.1% or better
- Span Drift ±25ppm/°C
- Zero Drift ±6µV/°C
- Wire Burn-out Detection
Ethernet Communications
- Compatibility IEEE 802.3, IEEE 802.3u
- Speed 10/100 Mbps
- No. of ports 1
- Port Connector 8-pin RJ-45
- Protection Built-in 1.5KV magnetic isolation
General
- Watchdog Timer System (1.6second) and Communication (programmable)
- Supports Peer to Peer mode 1
- Supports Graphical Condition Logic
- Supports Modbus/TCP,TCP/IP,UDP and HTTP Protocols
- Protection
- Overvoltage Protection ±35VDC
- Isolation Protection 2000VDC
- Built-in TVS/ESD Protection
- Power Reversal Protection
Mechanics
- Dimensions (H x W x D) 70 x 130 x 30mm
- Enclosure ABS + PC with solid mounting hardware
- Mounting DIN 35 rail, stack, wall
Power Requirements
- Power Input Unregulated 10 - 30VDC
- Power Consumption 2W @ 24 VDC
Environment
- Operating Temperature -10 to 70°C
- Storage Temperature -20 to 80°C
- Operating Humidity 20 to 95% RH (non-condensing)
- Storage Humidity 0 to 95% RH (non-condensing)